QUEST MEDICAL'S RETRACT-O-TAPEĀ® is an air-cushioned vascular loop designed to provide today's surgeon maximum control and visibility of the anastomotic site with minimal trauma to delicate tissue. Not only does it occlude vessels to stop the flow of blood to the anastamotic site, but it can be used to hold or position an organ to improve visualization of the site. Typically used in cardiovascular, thoracic vascular, orthopedic, and urological surgery, its features include:

TYPES AVAILABLE
Retract-O-Tape vascular loops are available in 5 different sizes, including a 10 gauge loop for gently handling large vessels (such as the saphenous vein) without a hemostat or clip.

NEW SADDLELOOP? DEVICES FOR OPCAB, ROBOTIC SURGERY, AND CONTINUOUS RETROGRADE CARDIOPLEGIA

SaddleLoop devices are part of the Retract-O-Tape family with radiopaque silicone tubing, 10 cm in length, with sealed ends to provide an air-cushioned surgical tool for manipulating anatomical organs and structures to either retract them or ligate vessels with minimum trauma.

Essential to robotic surgery is the unique integrated locking mechanism which maintains tension, without reducing visibility, and occludes with a single pass of the 18 gauge needle. Needle tips are available in blunt or semi-pointed.

Product Catalogue

Product Code

Product Description

Units/Case

1041

Blunt Needle Vascular Loop (Specially designed,

pre-attached, curved, blunt tip 18G needle) 18G

(.049? Diameter), 12? Length, Thin Wall - Sterile

20 each

1241

Blunt Needle Vascular Loop (Specially designed,

pre-attached, curved, blunt tip 18G needle) 18G

(.049? Diameter), 12? Length, Thin Wall ? Non-Sterile

100each

1541

SaddleLoop Occluding and Retracting Loop 18G, blunt tip

(.049? Diameter), 4? Length (10 cm)

16 each

1071

Semi-pointed Needle Vascular Loop (Specially designed,

pre-attached, curved, semi-pointed tip 18G needle) 18G

(.049? Diameter), 12? Length, Thin Wall ? Sterile

20 each

1271

Semi-pointed Needle Vascular Loop (Specially designed,

pre-attached, curved, semi-pointed tip 18G needle) 18G

(.049? Diameter), 12? Length, Thin Wall ? Non-Sterile

100 each

1571

SaddleLoop Occluding and Retracting Loop 18G, semi-pointed tip

(.049? Diameter), 4? Length (10 cm)

16 each

1001

Retract-O-Tape Vascular Loop 18G (.049? Diameter),

12? Length, Thin Wall ? Sterile

20 each

1201

Retract-O-Tape Vascular Loop 18G (.049? Diameter),

12? Length, Thin Wall ? Non-Sterile

100 each

1002

Retract-O-Tape Vascular Loop 16G (.066? Diameter),

12? Length, Thin Wall ? Sterile

20 each

1202

Retract-O-Tape Vascular Loop 16G (.066? Diameter),

12? Length, Thin Wall ? Non-Sterile

100 each

1012

Retract-O-Tape Vascular Loop 16G (.066? Diameter),

18? Length, Thin Wall ? Sterile

20 each

1212

Retract-O-Tape Vascular Loop 16G (.066? Diameter),

18? Length, Thin Wall ? Non-Sterile

100 each

1015

Retract-O-Tape Vascular Loop 10G (.131? Diameter),

18? Length, Thin Wall ? Sterile

10 each

1215

Retract-O-Tape Vascular Loop 10G (.131? Diameter),

18? Length, Thin Wall ? Non-Sterile

50 each

1032

Retract-O-Tape Vascular Loop 16G (.066? Diameter),

18? Length, Heavy Wall ? Sterile

20 each

1232

Retract-O-Tape Vascular Loop 16G (.066? Diameter),

18? Length, Heavy Wall ? Non-Sterile

100 each